Question 1 · Medical & Resuscitation · Easy
An intubated, ventilated patient is being prepared for an inter-hospital transfer. The transport monitor is displaying ECG, pulse oximetry, non-invasive blood pressure and temperature, and the escort is observing the patient continuously. Which further modality is a minimum requirement before departure?
- ACore–peripheral temperature gradient
- BInvasive intracranial pressure
- CContinuous cardiac output monitor
- DHourly urine output measurement
- EContinuous waveform capnography
Show answer
Answer: E
Continuous waveform capnography
The ICS/FICM minimum standards of monitoring during transport are continuous observation, cardiac rhythm (ECG), non-invasive blood pressure, oxygen saturation, temperature and, in intubated and ventilated patients, end-tidal carbon dioxide. The guidance states that capnography is mandatory in all intubated, ventilated patients; it is the monitor that tells you in a noisy, moving vehicle that the tube has displaced or the circuit has disconnected. The other options can be useful in selected patients but none is a minimum standard. Two related points are examined. Intermittent non-invasive blood pressure is sensitive to motion artefact, unreliable in a moving vehicle and a drain on the monitor battery, so an arterial line should normally be used. All monitors, including the ventilator display and syringe drivers, should be visible to the escorting staff, and alarms should be visible as well as audible.
Where this comes from
- Guidance On: The Transfer Of The Critically Ill Adult (2019)Intensive Care Society and Faculty of Intensive Care Medicine·19.1 Minimum standards of monitoring“End tidal carbon dioxide (ETCO2) in intubated / ventilated patients”Open PDF at page 23
- Guidance On: The Transfer Of The Critically Ill Adult (2019)Intensive Care Society and Faculty of Intensive Care Medicine·19.6 Capnography mandatory in intubated ventilated patients“Capnography / end tidal CO2 monitoring is mandatory in all intubated ventilated patients.”Open PDF at page 23
- Guidance On: The Transfer Of The Critically Ill Adult (2019)Intensive Care Society and Faculty of Intensive Care Medicine·19.2 Non-invasive blood pressure unreliable in a moving vehicle“Intermittent non-invasive blood pressure measurement is sensitive to motion artefact”Open PDF at page 23
- Guidance On: The Transfer Of The Critically Ill Adult (2019)Intensive Care Society and Faculty of Intensive Care Medicine·19.2 Invasive arterial monitoring should normally be used“arterial cannula should normally be used”Open PDF at page 23
- Guidance On: The Transfer Of The Critically Ill Adult (2019)Intensive Care Society and Faculty of Intensive Care Medicine·19.7 Recommendation 28: displays visible“All monitors, including ventilator displays and syringe drivers should be visible to accompanying staff.”Open PDF at page 23
- Guidance On: The Transfer Of The Critically Ill Adult (2019)Intensive Care Society and Faculty of Intensive Care Medicine·11.4 Portable monitors: alarms“Alarms should be visible as well as audible”Open PDF at page 17